TECHNOLOGY OF ACCUMULATING SAMPLING AT MASS SPECTROMETRIC METHOD OF TIGHTNESS INSPECTION
Abstract and keywords
Abstract (English):
The method of mass spectrometric method for total inspection of product tightness at atmospheric pressure is shown. This method can be applied to products of any size and configuration with a given inspection sensitivity. The method does not require vacuumizing of the monitoring objects.

Keywords:
leaktightness, mass-spectrometry, helium, inspection sensibility
References

1. GOST 28517-90. Kontrol' nerazrushayuschiy. Mass-spektrometricheskiy metod techeiskaniya. Obschie trebovaniya. - M.: Standartinform, 2005. - 7 c.

2. PNAE G-7-019-89 «Unificirovannaya metodika kontrolya osnovnyh materialov (polufabrikatov), svarnyh soedineniy i naplavki oborudovaniya i truboprovodov AEU. Kontrol' germetichnosti. Gazovye i zhidkostnye metody». - M.: Gosatomnadzor, 1989.

3. GOST R 50.05.01-2018. Sistema ocenki sootvetstviya v oblasti ispol'zovaniya atomnoy energii. Ocenka sootvetstviya v forme kontrolya. Unificirovannye metodiki. Kontrol' germetichnosti gazovymi i zhidkostnymi metodami. - M.: Standartinform, 2018. - 45 c.

4. MP 231-0030-2015. Techeiskateli mass-spektrometricheskie gelievye MS-4. Metodika poverki. Utv. GCI SI FGUP «VNIIM im. D. I. Mendeleeva», 2015.